技術(shù)參數(shù):
1. 測量參數(shù)Measure parameter:
◆放大倍數(shù)β:(0 - 999)
◆開關(guān)時間Switching time T :(0.01μS - 99.9μS),包括上升時間、存儲時間、下降時間。Including Tr、Ts、Tf
◆飽和壓降Vces:(0 - 2V)
◆正向壓降Vbe:(0 - 2V)
◆漏電流Leakage current Iceo:(0.01μA - 3mA)
◆耐壓Withstand voltage BVceo:(50V - 650V)
2. 測試條件 Testing conditions:
◆β測試Ib注入電流分三檔 β test three different Ib current:0.1mA、1.0mA、10mA。
◆開關(guān)時間測試Ic電流分四檔 Switching time test four different Ic current:0.5A、0.25A、0.1A、0.05A;對應(yīng)Ib電流為 the corresponding Ib current: 0.1A、0.05A、0.02A、0.01A。
◆Vbe、Vces的測試條件與開關(guān)時間測試條件相同The testing condition of Vbe and Vces is same as switching time testing condition.
◆漏電流Iceo測試電壓: 50V~650V連續(xù)可調(diào)。Test voltage for leakage current Iceo: 50V~650V adjustable.